Arizona Western College Mechanical Measurement & Flow Meter Lab Report Hi,I just need a Lab Report for Mechanical Measurement. The lab is about Flow Metering. I will provide you with the lab data and some photos of the FlowMeter Demonstration Rig.thanks Measurement of Fluid Flow
Chapter 15
Mechanical Measurements
By: Beckwith, Marangoni, and Lienhard
Fluid Flow Types
Movement of a liquid, gas, granular solid, or a
combination.
Liquid: Ex. Water
Gas: Ex. Air, steam, exhaust gases
Granular solid: Ex. Sand
Combination: Ex. Concrete, slurry (solids
suspended in a liquid)
Measurement Types
Direct Measure
Primary or Quantity Method
The weight or volume in a tank measured with respect
to time
Indirect Measures
Flow Meters
Velocity Probes
Flow Visualization
Direct Measurement
Measuring weight or volume with respect to
time
Weight of a tank
Graduated Cylinder
Bell Prover
Indirect Measure
Flow Meters:
Obstruction Meters: measures flow through
measuring pressure differentials
Venturi meter
Flow nozzles
Orifice
Variable Area meters
Obstruction Meters
Variable Area Meter
(Rotameter)
Three Forces act on the Float:
1. Weight
2. Buoyancy
3. Drag
Indirect Measure
Volume Flow Meters: measures volumetric
flow rate
Turbine and propeller meters
Electromagnetic flow meters
Vortex?shedding meter
Ultrasonic flow meter
Positive?displacement meters
zJwVqzxg
Indirect Measures
Mass Flow Meters
Coriolis Meter
Critical flow Venturi Meter
Thermal mass Flow Anemometers
http://www.processindustryinformer.com/videos/video/28/
Mass-flow-meters-explained
LDA
LDA
LDA
LDA
Indirect Measures
Velocity Probes
Pressure Probes
Total pressure and Pitot?static tubes
Direction?sensing probes
Hot?wire and Hot?film anemometers
Doppler?shift Measurement
Laser?Doppler Anemometry
Total pressure and Pitot?static tubes
Thermal Anemometry
Indirect Measures
Smoke trails and smoke wires
Dye injection
Hydrogen bubbles
Laser?induced fluorescence
eiMow&feature=related
http://video.foxnews.com/v/4056735/bigrig-wind-tunnel-test
Flow Characteristics
.
Mass Flow Rate:
m ? ?Q
.
Average Velocity:
Reynolds Number:
m Q
?
V?
?A A
?VD
Re D ?
?
Open Channel Flow
Measurement
Basic Environmental Technology
Chapter 2
Nathanson
Weir
Weir: is a dam or obstruction placed in the
channel so that the water backs up behind it
and then flows over it.
Sharp?crested weir: the sharp crest or edge
allows the water to spring clear of the weir
plate and to fall freely in the form of a nappe.
Weir
Flow Measurement with a Weir
There is a relationship between the height or
depth of water flowing over the crest and
discharge
Meter or yardstick
Automatic float?operated recording
Ultrasonic measuring
http://www.hycontrol.com/
Equations
Textbooks, handbooks, manuals
90° V-notch
Q ? 2.5 ? H
Q=discharge, ft3/s
H=head on weir, ft
2.5
Flumes
A specially shaped
constriction
Similar to a venturi
tube
Self cleaning
Little head loss and no
significant back?up of
sewage
Flow calculated by
water depth
http://www.plasti-fab.com
Parshall flume
H-flume
Trapezoidal flume
Metering manhole
Report Writing
Laboratory Note or Technical Memo
Very limited audience
Immediate supervisor
May be only one page
Sufficient information so you could reconstruct the situation possibly up to 5 years later
Full Report
Wider audience
Most likely still in your field
Format Example
Abstract
Introduction
Equipment
Procedure
Results
Conclusions and recommendations
Technical Paper
To make know the work of the writer
SAE papers or some other professional organization
Passive Voice
I prefer lab reports to be written in the Passive voice
rather than the Active Voice.
Do not use I, me, he, she, him, her or any names.
http://essayisay.homestead.com/passive.html
I broke the window. (Active)
The window was broken. (Passive)
Abstract
Summary of the entire report
Usually one page
Results and conclusions included
Introduction
Tell them what you are going to tell them
Overview of the work that is going to be
presented
History and reason for work
No results or conclusions
Objectives or thesis statement
What you are setting out to do
Report Body
Tell them
Equipment
Procedure
Results
Equipment
Describe the equipment used in the
experiment
Theory behind equipment operation
Theory behind sensor operation
Procedure
Physical test procedure
Calibration
Readings that will be taken
Test matrix
Describe what parameters and conditions will be
used for each test
Describe how the results will be analyzed
Equations
No results
Results
Tables and Graphs
Possibly Raw data
Values obtained from raw data
Comparisons to theory or other methods
Narrative of what is in each graph or table
Narrative of trends and comparisons
Conclusions and Recommendations
Tell them what you told them
Restate objectives or thesis statement
Summary of results
comparisons
Possible improvements
Ideas for future work
Figures, Tables, and Equations
Figures and tables
Include figures and tables when ever possible
Figures and tables can be used in any section of the report.
?Most will appear in the results section.
Figures and tables are very useful to the reader and help to
summarize data and findings
Equations
The equations used to obtain results are normally found in
the procedures section.
Make reference to and explain all figures, tables, and
equations in the narrative of the report
References
Include a separate reference page in your lab report.
All sources of information used should be referenced.
Give credit where credit is due.
Lab Manuals
Web Sites
Books
Periodical (magazines, journals, other publications)
Technical papers (SAE paper), Thesis or Dissertations
Time
Volume(1)
25.51
27.83
17.91
15.55
VAM (1/min)
2
4
4
5
h1
5
10
15
20
h2
233
260
305
365
220
217.5
205
187.5
Venturi
dh
h3
13
42.5
100
177.5
h4
227
242.5
270
310
h5
226
235
252.5
280
177
182.5
192.5
210
h6
178
185
195
215
Orifice
h7
h8
170
155
177.5
90
Weir
171
165
150
130
11
19
27
31
Time flow
4.70404
8.62379
13.40034
19.29260
MECH 4400
Flow Metering Lab
Due: 10/9/19
This report will be a full lab report. Fill in Table 1 with the raw data from the laboratory.
The results will be a calibration curve and equation for the venturi meter and orifice plate as a
function of pressure head difference. Also develop a calibration curve and equation for the weir
as a function of height above the base of the weir Lastly include the accuracy of the variable
area meter for each flow in the form of a percent error. The timed flow rate that can be obtained
from the measured time and volume will be used as the standard to develop the calibration
curves and percent error. Be sure to discuss possible sources of error in the conclusions and
recommendations section.
time
(s)
volume
(L)
VAM
(l/min)
5
h1
(mm)
10
15
20
Table 1: Flow Metering Lab Raw Data
h2
(mm)
h3
(mm)
h4
(mm)
h5
(mm)
h6
(mm)
h7
(mm)
h8
(mm)
weir
(mm)
Purchase answer to see full
attachment
Consider the following information, and answer the question below. China and England are international trade…
The CPA is involved in many aspects of accounting and business. Let's discuss some other…
For your initial post, share your earliest memory of a laser. Compare and contrast your…
2. The Ajax Co. just decided to save $1,500 a month for the next five…
How to make an insertion sort to sort an array of c strings using the…
Assume the following Keynesian income-expenditure two-sector model: AD = Cp + Ip Cp = Co…